Skip to content
akaturk Academic measurement

Article detail · 2026 · article

Effect of millimetric perforations on CO 2 diffusion and thermal transmittance of multi-layered breathing walls

ISSN1744-2591
YÖKSİS OpenAlex Open access · hybrid
Year2026
Citations0OpenAlex
Percentile%44.0
FWCI0.01.00 = world average
Scopus (SJR)Q2
WoS (JCR)Q3

Data source split

  • YÖKSİSYÖKSİS article record
  • YÖKSİS venueJournal of Building Physics
  • Catalog match (ISSN)Journal of Building Physics
  • OpenAlexOpenAlex enrichment (abstract, citations, topics)
  • Semantic Scholarcitation count (not merged with OpenAlex)

Abstract

OpenAlex English

The effect of 2 mm millimetric perforations on the performance of multi-layered breathing exterior wall systems was investigated in relation to both thermal transmittance and carbon dioxide (CO 2 ) diffusion. The study aimed to determine whether such perforations on glass fiber coated gypsum board (GFCGB) layers could enhance gas permeability without significantly compromising thermal insulation. Three wall configurations were prepared: a reference wall with unperforated GFCGB, and two alternatives with perforations of 2 mm spaced at 5 and 1 cm intervals. These were tested in a custom-built cold box setup designed to simulate indoor and outdoor conditions and allow simultaneous measurement of steady-state U values and effective CO 2 diffusion coefficients ( D EFF ). Results showed that the introduction of perforations increased D EFF value by 14% and 54% for the 5 and 1 cm intervals, respectively, compared to the unperforated reference. The measured U values of all testes systems, obtained by the cold-box tests under the steady-state laboratory boundary conditions, are within the range of 0.32–0.36 W/m 2 ·K. The findings suggest that improved gas diffusion may be achieved through carefully designed perforation patterns without substantial thermal penalty. This study represents the first application of the D EFF parameter to multi-layered wall systems composed of industrially available materials, marking a shift from material-scale evaluations to envelope-scale performance assessment. The perforated wall system proposed here offers a low-tech, scalable approach for breathable building envelopes, particularly relevant in settings where mechanical ventilation may be limited or absent. Overall, the study shows that air permeability, when quantified and optimized, can be treated as a functional property of building envelopes, contributing to healthier and more sustainable architectural solutions.

Topics

Citations

OpenAlex cited_by_count. Not a WoS or Scopus citation count; those sources have no separate column here.

0citationsOpenAlex · cited_by_count (cache / database)

Authors

2
  1. AYŞE DUMAN ORTA DOĞU TEKNİK ÜNİVERSİTESİ 1
  2. Başak Yüncü Karanfil 2