İçeriğe geç
akaturk Akademik ölçüm

OpenAlex konusu

Power Systems Fault Detection

Bu sayfa OpenAlex konu etiketine göre çalışmaları ve o konuda görünen akademisyenleri listeler. YÖKSİS temel alan / yan dal değildir.

OpenAlex 644 eser 42 yazar konusu

Çalışmalar

644 eser

  1. YÖKSİS SJR Q1 JCR Q3 OpenAlex 85.1%

    The requirements of an islanding, or 'loss of grid', protection for a dispersed storage and generation unit are examined, and the principal methods used for this type of relaying are outlined. A new protection algorithm is introduced which is based on the rate of change of power as measured at the generator's terminal…

  2. OpenAlex 85.4%

    Digital protection is based on the use of computers in power line relaying. Since the late 1960s, digital devices and techniques have been applied to almost all new protection schemes. Today the technology is moving towards standardised hardware platforms; at the software level, however, there remains a huge variety i…

  3. YÖKSİS SJR Q1 JCR Q1 OpenAlex üst %1 OpenAlex 99.1%

    Özet henüz yok.

  4. YÖKSİS SJR Q1 JCR Q1 OpenAlex üst %1 OpenAlex 99.2%

    Özet henüz yok.

  5. YÖKSİS SJR Q1 JCR Q1 OpenAlex üst %10 OpenAlex 97.8%

    Inverter-Based Resources (IBRs), including Wind turbine generators (WTGs), exhibit substantially different negative-sequence fault current characteristics compared to synchronous generators (SGs). These differences may cause misoperation of customary negative-sequence-based protective elements set under the assumption…

  6. YÖKSİS SJR Q1 JCR Q1 OpenAlex üst %10 OpenAlex 98.9%

    Özet henüz yok.

  7. YÖKSİS SJR Q1 JCR Q2 OpenAlex 87.0%

    In recent years, there has been a growing interest in incorporating microgrids in electrical power networks. This is due to various advantages they present, particularly the possibility of working in either autonomous mode or grid connected, which makes them highly versatile structures for incorporating intermittent g…

  8. YÖKSİS SJR Q1 JCR Q4 OpenAlex 89.1%

    Özet henüz yok.

  9. YÖKSİS SJR Q1 JCR Q4 OpenAlex 89.5%

    Özet henüz yok.

  10. YÖKSİS SJR Q1 JCR Q3 OpenAlex 14.2%

    The ability to detect when dispersed storage and generation (DSG) units become islanded from the main source of generation enables the DSG to be quickly disconnected from the utility network and for that network to be rebuilt in a safe and orderly manner. The new islanding protection algorithm described in the paper h…

  11. YÖKSİS SJR Q1 JCR Q1 OpenAlex üst %1 OpenAlex 99.0%

    Özet henüz yok.

  12. YÖKSİS SJR Q1 JCR Q3 OpenAlex üst %10 OpenAlex 98.3%

    Inverter-based resources (IBRs) exhibit different short-circuit characteristics compared to traditional synchronous generators (SGs). Hence, increased uptake of IBRs in the power system is expected to impact the performance of traditional protective relay schemes—set under the assumption of a SG-dominated power system…

Akademisyenler

42 akademisyen