Estimation of contrast-to-noise ratio in CT and CBCT images with varying scan settings in presence of different implant materials.

ISSN0250-832X
YÖKSİS OpenAlex Açık erişim · green
Yıl2019
Atıf8OpenAlex
Yüzdelik%67,7
FWCI0,511,00 = dünya ortalaması
Scopus (SJR)Q1

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıDENTOMAXILLOFACIAL RADIOLOGY
  • Katalog eşleşmesi (ISSN)Dentomaxillofacial Radiology
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)

Özet

OpenAlex İngilizce

Objectives: To assess the contrast-to-noise ratio (CNR) of four different types of dental implant materials in CT and cone beam CT (CBCT) images with varying scan settings. Methods: Four different types of implants: zirconium (Zr), titanium (Ti) Grade 4 and 5 and titanium–zirconium (Ti–ZrO2) alloy were placed in a 3% gelatin phantom in a cylindrical plastic container and scanned with two different CT machines (GE Medical systems and Toshiba Medical Systems) and one CBCT machine (I-CAT, Imaging Sciences International) with different voxel sizes of 0.2, 0.25, 0.3 and 0.4 mm. Images were analyzed using ImageJ software with the purpose of estimating the CNR. Results: The CNR obtained from images acquired with CT was lower than the CBCT with all voxel sizes tested. 0.3 and 0.4 mm voxel sizes exhibited the highest CNR (p < 0.05) that gives the best image quality. Among the implant materials tested, titanium Grade 5 has the highest levels of CNR while Zirconium has the lowest (p < 0.05). Conclusions: The optimum protocol for radiographic follow-up in areas near implants on the I-CAT is low-resolution settings (0.3 and 0.4 mm voxel sizes) which gave the highest CNR thus image quality. In presence of Zr implants, an alternative imaging modality (i.e., MRI) may be considered to avoid low-quality images.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

8atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 3 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. 2024 The influence of the field of view and voxel size on the contrast-to-noise ratio in cone-beam computed tomography imagingAtıf 5 · OpenAlex
  2. 2024 The influence of the field of view and voxel size on the contrast-to-noise ratio in cone-beam computed tomography imagingAtıf 5 · OpenAlex
  3. 2026 Effects of Dental Material-Induced Artifacts on Signal-to-Noise Ratio (SNR) and Contrast- to-Noise Ratio (CNR) in CBCT: An In Vitro StudyAtıf 0 · OpenAlex

Yazarlar

5
  1. EMİNE ŞEBNEM KURŞUN ÇAKMAK ANKARA YILDIRIM BEYAZIT ÜNİVERSİTESİ 1
  2. HÜSNİYE DEMİRTÜRK KOCASARAÇ 2
  3. SEVAL BAYRAK 3
  4. GÜLBAHAR USTAOĞLU 4
  5. Marcel Noujeim 5