Determination of Some Heavy Metal Ions with a Carbon Paste Electrode Modified by Poly glycidylmethacrylate methylmethacrylate divinylbenzene Microspheres Functionalized by 2 Aminothiazole

ISSN1040-0397
YÖKSİS OpenAlex
Yıl2008
Atıf23OpenAlex
Yüzdelik%74,1
FWCI1,241,00 = dünya ortalaması
Scopus (SJR)Q2
WoS (JCR)Q1

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıElectroanalysis
  • Katalog eşleşmesi (ISSN)Electroanalysis
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

Abstract A carbon paste electrode modified with 2‐aminothiazole functionalized poly(glycidylmethacrylate‐methylmethacrylate‐divinylbenzene) microspheres was used for trace determination of mercury, copper and lead ions. After the open‐circuit accumulation of the heavy metal ions onto the electrode, the sensitive anodic stripping peaks were obtained by square wave anodic stripping voltammetry (SWASV)). Many parameters such as the composition of the paste, pH, preconcentration time, effective potential scan rate and stirring rate influence the response of the measurement. The procedures were optimized for most sensitive and reliable determinations of the desired species. For a 10‐min preconcentration time in synthetic solutions at optimum instrumental and experimental conditions, the detection limit (LOD) was 12.3, 2.8 and 4.5 μg L−1 for mercury, copper and lead, respectively. The limits of detection may be enhanced by increasing the preconcentration time. For example, LOD of mercury and copper was 4.9 and 1.0 μg L−1 for fifteen minutes preconcentration time. The sensitivity may also considered to be increased by using a more suitable electrode composition targeting the more conductive electrode with lesser amount of modified polymer for sub‐μg L−1 levels of heavy metal ions. The optimized method was successfully applied to the determination of copper in tap water and waste water samples by means of standard addition procedure. The copper content found was comparable with the certified concentration of the waste water sample. The calibration plots for mercury and lead spiked real samples were also drawn.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

23atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yerel katalogda bu makaleye atıf yapan 4 yayın (OpenAlex referans eşleşmesi; tam dünya listesi değildir).

  1. 2010 Separation preconcentration and inductively coupled plasma mass spectrometric ICP MS determination of thorium IV titanium IV iron III lead II and chromium III on 2 nitroso 1 naphthol impregnated MCI GEL CHP20P resinAtıf 211 · OpenAlex
  2. 2018 Rapid and Sensitive Determination of Hg(II) Using Polarographic Technique and Application to Chlorophytum comosumAtıf 4 · OpenAlex
  3. 2018 Rapid and Sensitive Determination of Hg(II) Using Polarographic Technique and Application to Chlorophytum comosumAtıf 4 · OpenAlex
  4. 2018 Simultaneous voltammetric analysis of lead, copper and mercury ions by carbon paste electrode based on 1-(3-aminopropyl) imidazole modified polymerAtıf 3 · OpenAlex