İçeriğe geç
akaturk Akademik ölçüm

Makale detayı · 2024 · article

Scleral-fixated intraocular lens implantation with “irregular, knotless, zigzag-shaped scleral tunnel suture technique” combined with pars plana vitrectomy or anterior vitrectomy

ISSN1319-4534
YÖKSİS OpenAlex Açık erişim · green
Yıl2024
Atıf1OpenAlex
Yüzdelik%55,7
FWCI0,391,00 = dünya ortalaması
Scopus (SJR)Q3
WoS (JCR)Q3

Veri kaynağı ayrımı

  • YÖKSİSYÖKSİS makale kaydı
  • YÖKSİS dergi adıSaudi Journal of Ophthalmology
  • Katalog eşleşmesi (ISSN)Saudi Journal of Ophthalmology
  • OpenAlexOpenAlex zenginleştirmesi (özet, atıf, konular)
  • Semantic Scholaratıf sayısı (OpenAlex ile birleştirilmez)

Özet

OpenAlex İngilizce

PURPOSE: This study aims to introduce a new suture method and report surgical outcomes of patients who underwent scleral-fixated intraocular lens (SF-IOL) implantation combined with either pars plana vitrectomy (PPV) or anterior vitrectomy (AV). METHODS: Twenty-three eyes performed SF-IOL implantation combined with PPV (Group 1), and 34 eyes performed SF-IOL implantation combined with AV (Group 2) were included in the study prospectively. The SF-IOL, either polymethyl methacrylate or foldable IOL, was sutured into the sclera using PC-9 sutures in an irregular, knotless, and zigzag-shaped manner. The scleral tunnel was approximately 12-15 mm long, with at least four sharp edges. Suture tips were trimmed within the scleral tunnel. Postoperative outcomes and complications were evaluated. RESULTS: Both groups showed no complications such as suture tip expulsion, suture reaction, IOL dislocation, or increased intraocular pressure during postoperative visits. Group 1 exhibited a statistically significant improvement in visual acuity compared to preoperative values ( P = 0.036 for the 1 st month, <0.001 for the 3 rd month). Similarly, Group 2 demonstrated a statistically significant improvement in visual acuity compared to the preoperative period ( P = 0.001 for the 1 st month, <0.001 for the 3 rd month). CONCLUSION: The “irregular, knotless, and zigzag-shaped scleral tunnel suture technique” yielded favorable results in terms of IOL stability and visual acuity. This technique can be safely employed in patients undergoing SF-IOL implantation combined with PPV or AV.

Konular

Atıflar

OpenAlex cited_by_count. WoS veya Scopus atıf sayısı değildir; o kaynaklar için ayrı kolon yoktur.

1atıfOpenAlex · cited_by_count (önbellek / veritabanı)

Yazarlar

4
  1. ABUZER GÜNDÜZ 1
  2. EMRAH ÖZTÜRK 2
  3. CEM ÇANKAYA 3
  4. PAMUK BETÜL ULUCAN ATAŞ İZMİR BAKIRÇAY ÜNİVERSİTESİ 4